Private Rental Information
The facility is available for private rental on a limited basis to both Non-profit 501(c)(3) and For-profit organizations.
Technical Specifications
House/Stage Box
- Proscenium Stage - Proscenium Width 44' Height 19". Plaster Line to Back Wall 25".
- Plaster Line to apron edge 7"5'
- Apron Width 63'5".
- Wing Space is Limited. Stage Right 6" Stage Left 9".
- Stage Deck is HD masonite sheet 4x8.
- No trap use. US and CS.
- College does not provide ballet floor (Marley) other than through contractual arrangement.
- All electrics and masking battens are dead hung. Heights vary (see elevation), minimum 11'9".
- Facility is not equipped with counter-weighted fly lines.
- Stage has no fly space.
- Permanent stairs from apron right and left.
- House has 330 fixed seats + 6 handicap access positions in Row N
- No oversell or SRO - Fire codes prohibit SRO audience. Maximum occupancy at all times 336 people.
- Seating is numbered.
- House is raked, with continental seating.
- Performer crossover behind soft cyc with crossover lighting controlled by switch on upstage wall.
- Backstage AC is limited to (2) 20A circuits.
- AC outlets located in both wings.
- Additional 15A AC circuit and outlets located in house under apron.
- Work lights controlled by switch on stage left and stage right wall or from control booth.
- Main rag on a fixed rate motorized pull.
- Trim-to-trim is approximately 17 seconds. There is no manual override.
- Facility is on computer zone climate control. No manual control of air handlers.
- Three exit doors at rear of house. Direct egress from apron stage right in emergency.
- Fire extinguishers prominently located throughout facility. C02 extinguishers stage left at patch panel and down stage right wing.
Soft Goods
- 6 black legs 16'xl6" on tracks. (No full coverage to CS)
- Full black traveler upstage. (Full coverage just DS of soft cyc)
- Full US soft white cyc
- Teasers trimmed at a varied heights minimum 11"9'
- Electric Main Drape is cranberry and parts at center. (17 sec move time – single speed).
- Drape is motor driven and controlled from booth. NO manual pull.
- Movie screen is front projection height 20", width 18". Screen falls 6" upstage of plaster line.
- Movie screen is motorized and controlled from booth. Single speed at approx 28 sec.
- Panasonic DZ6700 WUXGA Projector. Hung center back of house. 30ft from screen.
Lighting Control
- (227) 2.4K dimmers (Combination of ETC Sensor, Sunburst SB400 and Strand CD80 racks)
- Box Booms and balcony rail operate on (12) 2.4K (Sunburst SB400) dimmers.
- ETC Ion 1000 console.
Lighting Inventory
The following instruments are permanently hung for rep plot and are subject to change per Tech Director only. No rehang/focus/color is permitted without prior agreement with TD.
FOH: Dimmer(s) 1 thru 30
- (12) Source 4 / 36
- (12) Source 4 / 26
- (2) Source 4 / 50
- (1) Studio Collor 575 movers
- (2) Elation Power Wash 575e movers
1st Electric: Dimmer(s) 43 thru 72
- (12) Source Four 36
- 2nd ELECTRIC: Dimmer(s) 73 thru 102
- (12) Source Four 36
3rd Electric: Dimmer(s) 103 thru 132
- (12) Source Four 36
4th Electric: Dimmer(s) 133 thru 162
- (5) ETC ColorSource Cyc
- (2) ETC Source Four 50
Box Boom: Dimmers 35 thru 42
- HL: (8) Century 6 x 9 with stepped lenses: No gobo slots
- HR: (8) Century 6 x 9 with stepped lenses: No gobo slots
Balcony Rail: Dimmers 31 thru 34
- HL: (2) Source 4 / 50
- HR: (2) Source 4 / 50
Hi-Side Ladders: Dimmer(s) 163 thru 186
- SL: (6) Source 4 / 50
- SR: (6) Source 4 / 50
Lighting Notes
- FOH beam is very HIGH at approximately 60 degrees.
- All electrics follow FOH into HIGH, sixty-degree focus.
- A bar of back light LED units consisting of (6) COLORado 1-tri tour PAR and (4) Chauvet Intimidator Spot 260
- (2) 1000 W spot units in tech booth in back of house, HL and HR
Audio Overview
- Console: Behringer X32
- Mains: HL / HR – Community IP6 – 1122/94B 12' 2 Way ~ Center cluster – Community IP6 – 1122/94B 12' 2 Way x 2
- Power Amps: QSC (Mains/ Aux monitors)
- Monitors: (5) QSC K10.2 wedges (5) JBL deck wedges available upon request. (No loft mounted monitors)
- (12) Shure SM - 58 with various cable runs
- (4) Shure SM - 57
- (5) directional mics available (ADK/ Shure)
- Boom Stands
- Tascam CD- 200SB Player in booth
- Samsung DVD Player
- Barco ClickShare wireless computer presentation unit & dongles (2)
Audio Notes
- No AD Amp available
- House acoustics are excellent/light slap.
- 16 Channel Snake can be pulled from SR to CS
- Behringer S16 SR with 16 channel snake that can be pulled from SR to CS
- 4 ¼'' returns on one of the audio snakes.
- DMX may return on the audio snake if necessary.
Dressing Room
- 1 dressing room located backstage to accommodate 4-8 performers. Fluorescent lighting, counters, mirrors, and chairs. Hot and cold running water in the adjacent room.
- 1 greenroom space located next to dressing room. Accommodates up to 12 performers.
- Large staging area
- 1 Restroom
- 1 additional dressing room (available only upon request) 1 full flight down accommodates 10-12 performers includes a private bathroom.
- No showers
- No Laundry machines
Additional Equipment
- Additional equipment is available for use ONLY through prior arrangement.
- (4) COLORado Tri-tour RGB Par
- (2) Hurricane Haze 3d
- (4) Wireless ClearCom units, with (1) additional wired location at the audio board.
- Yamaha grand piano 9' available through prior arrangement.
- Pearl Drum Kit (12' 14' 16' Toms 22' Kick)
- Yamaha Drum Kit (12' 14' 16' Toms 22' Kick)
- Basic hand tools and stage hardware are available at the discretion of the tech director.
- Campus cafeteria open during regular day and evening class hours. Vending machines are accessible at off hours.
- Smoking, food & beverages are strictly prohibited on stage, backstage and in the house.
- Crew consists of Tech Director to insure working order of all house equipment, other than through contractual agreement.
Access to Building/Parking
- Loading dock door is 10" wide x 12" high and 3"2' above ground level.
- Loading dock area is a township fire zone.
- After load - in, all vehicles must be immediately moved to the visitor's parking (see map) unless arranged directly with security.
- Parking in fire lanes, fire zones and area designated as 'RESERVED' is strictly prohibited.
Campus Security
- Security officers can be reached at 215-968-8911 24 hrs., or through emergency radio phones prominently located in parking lots A-D indicated by blue lights.
- Officers will offer assistance upon call.
- Security officers are in direct contact with local police and ambulance.
- Security gates are locked by 11:30 PM.
- All personal must exit the facility by 11:00 PM.
- Under no circumstance will a rehearsal or performance be permitted to continue beyond 11:00 PM.